NABCEP PV Associate · practice test · keys checked against the 2026 job task analysis
This NABCEP practice test targets the PV Associate (PVA) exam with 30 practice questions, not NABCEP questions, drawn from the six domains tested since April 7, 2026. Once you choose an answer, each option gets a short note, why it works or where it goes wrong; no account is needed.
20% Safety
20% Core knowledge
10% Sales & economics
18.3% Design
18.3% Installation
13.3% O&M
How the PV Associate job task analysis (April 7, 2026) splits the scored items. [PROG][JTA]
PV Associate practice questions
Score: 0 of 0 picked correctly · 30 items here
Q1 · Safety · 20%
Why does pulling apart a PV connector pair while a string is carrying current tend to draw a longer-lasting arc than opening an AC circuit at a similar voltage?
One tap per item counts toward the score; opening the key first leaves the item unscored.
Skip ahead to the key and the reasoning
Opening the connector drives the string current toward zero, not upward; current rises toward Isc only under a short circuit.
Alternating current falls to zero twice each cycle, which helps an arc go out; direct current never does, so the arc can sustain itself across the widening gap.
Bypass diodes route current around shaded cells and hold no meaningful stored charge, so they do not feed an arc at the connector.
PV connectors are listed for DC PV circuits; the arc comes from breaking DC under load, which the connector instructions forbid.
Q2 · Safety · 20%
A homeowner presses the rapid shutdown initiator on a rooftop system with module-level electronics. Which statement about the array afterward is accurate?
Skip ahead to the key and the reasoning
Within the time limit the roof wiring is brought down to a lower voltage, not made dead; the lit modules themselves keep generating.
Rapid shutdown acts on the PV circuits; the service conductors stay energized from the utility until the utility itself disconnects them.
The inverter enclosure is not the only place a hazard remains; on the roof, module leads can still carry voltage from the lit cells.
Rapid shutdown limits the voltage on the conductors leaving the module electronics, but the cells keep generating in light, so each module and its leads can still be energized.
Q3 · Safety · 20%
In an off-grid system with a flooded lead-acid battery bank, when does the bank give off the most hydrogen, making ventilation and spark control most critical?
Skip ahead to the key and the reasoning
A full bank at rest has no charging current pushing past what the plates can absorb, so it gives off very little gas.
Discharging the bank into loads at night produces little gas; gassing builds toward the end of charging, not during discharge.
An idling inverter draws only a small standby current from the bank, a light discharge with almost no gassing.
An equalizing charge deliberately holds a flooded bank above its normal charging voltage to mix and balance the cells, which drives the heaviest gassing of hydrogen and oxygen.
Q4 · Safety · 20%
An inverter displays a ground-fault alarm on a sunny afternoon. Before touching the array wiring or racking, what should the technician assume?
Skip ahead to the key and the reasoning
A fault can involve either polarity, and the fault path itself can energize metal parts, so the hazard is not limited to the positive conductor.
A ground fault puts current where it does not belong, so racking, frames or a conductor that normally sits near ground potential can be energized until testing proves otherwise.
The ground-fault protection stops the inverter, but the damaged wiring that caused the alarm is still there and can stay energized.
A ground-fault alarm on a PV inverter points to the DC array circuits, exactly where the technician is about to work.
Q5 · Safety · 20%
Design documents list a string's maximum system voltage as 480 V DC, while its normal operating voltage is about 380 V. Which instrument is suitable for checking the string's open-circuit voltage?
Skip ahead to the key and the reasoning
Open-circuit voltage is the highest voltage the string produces, so the meter and its leads must be rated above the 480-V maximum, as a 600-V meter is, and set to read DC.
A 400-V rating covers the operating voltage but not the higher open-circuit voltage, so this meter would be used beyond its rating.
Non-contact testers sense the changing field around AC conductors and give no reliable indication on a steady DC circuit.
An AC voltage range is not set up to read the steady DC voltage of a PV string, so the reading would be wrong or zero.
Q6 · Safety · 20%
Why do battery manufacturers call for insulated or taped tools when tightening terminal connections on a 48-V battery bank?
Skip ahead to the key and the reasoning
Brief contact with a wrench does not magnetize a lead or copper terminal, and the monitor does not depend on terminal magnetism.
A battery can deliver thousands of amperes into a short, so an uninsulated wrench across two terminals can weld, arc and throw molten metal.
Rust from a tool is not the concern; terminal resistance depends on clean, properly torqued contact surfaces.
At 48 V the main danger is the short-circuit arc between terminals, not current flowing through the installer's body.
Q7 · Core knowledge · 20%
Sixteen modules (Voc 49.5 V, Isc 13.9 A at STC) are wired as two parallel strings of eight. What are the array's open-circuit voltage and short-circuit current at STC?
Skip ahead to the key and the reasoning
Worked answer: B
String voltage, 8 modules in series
8 × 49.5 V
=
396.0 V
Array current, 2 strings in parallel
2 × 13.9 A
=
27.8 A
Array open-circuit voltage and short-circuit current
396.0 V and 27.8 A
49.5 V and 222.4 A treats all 16 modules as parallel: the voltage stays at one module's Voc while all 16 currents add.
Modules in series add voltage (8 × 49.5 V = 396.0 V), and strings in parallel add current (2 × 13.9 A = 27.8 A).
The 396.0 V for eight modules in series is right, but 13.9 A is one string; the two parallel strings add their currents.
792.0 V and 13.9 A wires all 16 modules into a single series string instead of two strings of eight.
Q8 · Core knowledge · 20%
In a stand-alone PV system with a battery bank, what does the charge controller mainly do?
Skip ahead to the key and the reasoning
DC-to-AC conversion is the inverter's job; a charge controller works on the DC side.
A stand-alone system has no utility connection, and synchronizing is an inverter function anyway.
Ground-fault detection is a separate protective function, not the charge controller's main role.
The charge controller limits current and voltage from the array as the batteries fill, protecting them from overcharge.
Q9 · Core knowledge · 20%
An installer runs a bare copper conductor from the grounding bus of a home's service panel to a newly driven ground rod. What is this conductor called?
Skip ahead to the key and the reasoning
An equipment grounding conductor runs with the circuit conductors and bonds equipment back to the source; it does not land on the rod.
The grounded conductor, usually the neutral, carries normal current in the circuit and is not run out to a ground rod.
The main bonding jumper joins the neutral bus to the grounding bus inside the service equipment; it does not leave the panel.
The conductor that connects the system or service equipment to a grounding electrode, such as a driven rod, is the grounding electrode conductor.
Q10 · Core knowledge · 20%
A chimney shades one cell group of a module in a series string. What does that module's bypass diode do?
Skip ahead to the key and the reasoning
Stopping reverse current from a battery at night is the job of a blocking diode or the charge controller, not the bypass diodes in the junction box.
A conducting bypass diode takes the shaded group's voltage out of the module's output; it cannot add voltage to compensate.
When shaded cells can no longer pass the string current, the bypass diode conducts around that group, limiting the loss and preventing a hot spot.
Rapid shutdown comes from module-level electronics or switches; a bypass diode is a passive part with no shutdown function.
Q11 · Core knowledge · 20%
A chimney will shade two of twelve modules on a roof every morning. Why might a designer choose microinverters over a single string inverter for this array?
Skip ahead to the key and the reasoning
With an inverter on each module, a shaded module lowers only its own output instead of pulling down a whole series string.
Microinverters put AC wiring on the roof; the trunk cable that collects their output is an AC circuit.
Module frames, racking and the microinverters themselves still need equipment grounding.
Grid-tied microinverters must stop exporting when the utility fails, like any other grid-tied inverter.
Q12 · Core knowledge · 20%
A typical US home has a split-phase service with 120 V from each hot leg to the neutral. What voltage is measured between the two hot legs?
Skip ahead to the key and the reasoning
120 V is each hot leg to the neutral; measured leg to leg, the two 120-V halves add.
208 V is line to line on a 120/208-V three-phase wye service, where the phases are 120 degrees apart.
The two legs come from opposite ends of a center-tapped transformer winding, so their voltages add to 240 V.
277 V is line to neutral on a 480Y/277-V three-phase commercial service, not a split-phase home.
Q13 · Sales & economics · 10%
A customer's utility charges its highest rates from 4 p.m. to 9 p.m. and credits midday exports at a low rate. Which addition lets the customer put more of their existing solar output toward the 4–9 p.m. rates?
Skip ahead to the key and the reasoning
East-facing modules add new output in the morning, an off-peak period; they move none of the existing midday output into the evening.
Shifting stored midday energy into the 4–9 p.m. window offsets the highest-priced kWh instead of exporting it for a low credit.
Recovering clipped energy adds a little production at midday, exactly when exports earn the low credit.
A production meter measures the output but changes neither when the energy is used nor what it is worth.
Q14 · Sales & economics · 10%
During a first sales visit, which information best shows a household's annual electricity use?
Skip ahead to the key and the reasoning
The main breaker rating shows the service capacity, not how much energy the household actually uses.
One summer bill misses the seasonal pattern; winter and shoulder-month use can differ widely.
Size and age hint at usage but cannot replace the consumption the utility actually measured.
Twelve months of billed or interval usage data capture the seasonal swings in use and are the basis for sizing and savings estimates.
Q15 · Design · 18.3%
A 7.2-kW (DC) array sits at a site averaging 4.5 peak sun hours per day. Using an overall derate factor of 0.78, about how much AC energy should it produce in a year?
Skip ahead to the key and the reasoning
Worked answer: C
Daily DC energy
7.2 kW × 4.5 h
=
32.4 kWh
Daily AC energy after derates
32.4 kWh × 0.78
=
25.272 kWh
Yearly energy
25.272 kWh × 365
=
9,224 kWh
Estimated annual production
about 9,224 kWh
2,602 kWh multiplies by the 0.22 lost to derates instead of the 0.78 that remains.
7,195 kWh applies the 0.78 derate twice.
7.2 kW × 4.5 h × 0.78 = 25.272 kWh a day, and × 365 days ≈ 9,224 kWh a year.
11,826 kWh leaves out the derate, as if the array delivered its full DC rating as AC.
Q16 · Design · 18.3%
A design pairs 26 modules rated 410 W with a 7.6-kW (AC) inverter. What is the DC-to-AC ratio?
Skip ahead to the key and the reasoning
Worked answer: C
Array DC rating
26 × 410 W
=
10,660 W
DC-to-AC ratio
10.66 kW ÷ 7.6 kW
=
1.40
DC-to-AC ratio
1.40
0.71 divides the inverter rating by the array rating, the inverse of the DC-to-AC ratio.
1.12 inflates the inverter rating by 125% before dividing, a factor that belongs to conductor and overcurrent sizing, not to this ratio.
26 × 410 W = 10.66 kW of DC, and 10.66 kW ÷ 7.6 kW = 1.40.
1.75 multiplies the correct ratio by 1.25, adding an overcurrent-sizing factor the ratio does not use.
Q17 · Design · 18.3%
A site surveyor aims a fixed residential array with a compass where the magnetic declination is 12° east. For the most annual energy, which way should the array face?
Skip ahead to the key and the reasoning
A compass points to magnetic south, here 12° away from true south, so aiming by the raw reading turns the array off its best azimuth.
A west-facing array catches only the afternoon sun; correcting the compass does not fix a wrong direction.
In the continental US a fixed array collects the most annual energy facing true south, and the compass reading has to be adjusted by the local declination to find it.
An east-facing array gives up the afternoon sun, losing far more energy than cooler mornings gain.
Q18 · Design · 18.3%
Which period does a shading assessment usually treat as the solar window for a fixed array used all year?
Skip ahead to the key and the reasoning
Most of a day's energy arrives between about 9 a.m. and 3 p.m. solar time, and the low winter sun casts the longest shadows, so that window on the winter solstice captures the worst shading of the year.
At solar noon in summer the sun is at its highest and shadows are shortest, so a single check then misses most shading.
The equinoxes show a middle sun path and miss the low winter sun, while the early and late hours add little energy.
A two-hour summer window ignores the low-sun months, when nearby objects shade the array the longest.
Q19 · Design · 18.3%
Why do fire codes require clear pathways and setbacks around arrays on many residential roofs?
Skip ahead to the key and the reasoning
Module cooling depends on the mounting standoff behind the modules, which the fire code spacing does not address.
Access pathways and setbacks let firefighters move across the roof and cut ventilation openings without working on top of energized modules.
Dead load is checked in the structural review of the framing; the fire code spacing is about firefighter access.
Appearance is a zoning or design-review matter; fire codes do not regulate how the array looks.
Q20 · Design · 18.3%
Which plan-set drawing shows the electrical path from the array through the inverter to the point of interconnection, with conductor sizes and overcurrent device ratings?
Skip ahead to the key and the reasoning
The site plan shows where the array and equipment sit on the property and roof, not the circuit ratings.
An attachment detail shows how the racking fastens to the roof framing, not the electrical path.
A datasheet gives one product's ratings, not the wiring of the whole system.
A one-line (single-line) diagram traces the circuit from the modules through disconnects and the inverter to the interconnection, labeling conductors and overcurrent devices.
Q21 · Installation · 18.3%
Where should the lag screw of a roof attachment be driven on a typical wood residential roof?
Skip ahead to the key and the reasoning
Decking alone is too thin to hold a lag screw against wind uplift; the screw must reach the framing.
A lag near the edge is more likely to split the wood or exit the side of the rafter, not less.
The rafter or truss chord carries the load, and a lag centered in it gets full thread engagement without breaking out the side.
Fascia is trim fixed to the rafter ends, too light to carry array loads.
Q22 · Installation · 18.3%
Why should PV source-circuit conductors be secured to the racking instead of lying on the roof surface?
Skip ahead to the key and the reasoning
Wire left on the roof rubs against the surface each time the wind moves it, and the scraping, plus water and debris, wears through the insulation.
The roof surface has no effect on the circuit voltage, which is set by the modules.
Intact insulation keeps the conductor isolated from the roof; a ground fault appears only after the jacket is damaged.
Where the wire lies does not change the array's output as long as the conductor is intact.
Q23 · Installation · 18.3%
A module's leads end in one brand of PV connector, and the home-run cable has a look-alike connector from another brand. What should the installer do?
Skip ahead to the key and the reasoning
A firm click does not prove the contact metals, dimensions and seals match; look-alike connectors from different makers can heat up over time.
Connectors are tested and listed as mating pairs; joining different brands without the makers' compatibility listing can leave a poor contact that overheats.
Tape does not fix a mismatched contact; the problem is inside the connector, where pin and socket may not mate properly.
Equal voltage ratings do not show that the two designs mate safely; compatibility comes from the listing.
Q24 · Installation · 18.3%
Why does an installer form a drip loop where a cable runs down into a fitting on the side of an outdoor enclosure?
Skip ahead to the key and the reasoning
Thermal movement is handled by expansion fittings on long raceway runs, not by a small loop at an entry.
Spare length kept for future service is a service loop, which has a different purpose from a drip loop.
A loop adds a little length, if anything, so it does not reduce voltage drop.
Water running along the cable drips off the bottom of the loop, so it does not follow the cable into the enclosure.
Q25 · Installation · 18.3%
Why should installers avoid standing or kneeling on modules during installation?
Skip ahead to the key and the reasoning
Polarity is fixed by how the cells are wired; pressure cannot reverse it.
Open-circuit voltage depends on cell temperature and light, not on weight on the glass.
Point loads flex the laminate and can cause microcracks in the cells that later grow into hot spots and power loss.
Bypass diodes sit in the sealed junction box, and foot pressure on the glass does not wear them.
Q26 · O&M · 13.3%
A 400-W module has a power temperature coefficient of −0.35%/°C. On a 35 °C afternoon its cells reach 60 °C. With irradiance at 1,000 W/m², about what power should it produce?
Skip ahead to the key and the reasoning
Worked answer: A
Cell temperature above STC
60 °C − 25 °C
=
35 °C
Power loss
35 × 0.35%
=
12.25%
Expected power
400 W × (1 − 0.1225)
=
351 W
Output with 60 °C cells
about 351 W
The cells are 60 − 25 = 35 °C above STC, so power falls 35 × 0.35% = 12.25%, and 400 W × 0.8775 ≈ 351 W.
386 W uses the 35 °C air temperature instead of the cell temperature, correcting for only 10 °C.
400 W is the STC rating, which assumes 25 °C cells; hot cells produce less.
449 W adds the 12.25% instead of subtracting it; a negative coefficient means power drops as cells heat up.
Q27 · O&M · 13.3%
Over a dry summer with no rain, monitoring shows a system's output slowly falling to about 15% below expected on every string, with no inverter alarms. What should be checked first?
Skip ahead to the key and the reasoning
A slow, even decline on every string during a dry spell, with no alarms, fits soiling, which builds until rain or cleaning removes it.
One failed bypass diode affects a single module, not every string by the same amount.
A tripped breaker would drop output to zero and raise an alarm, not cause a slow 15% decline.
Even first-year degradation is usually a few percent at most, far smaller than a 15% drop that builds over one summer.
Q28 · O&M · 13.3%
On a partly cloudy afternoon, monitoring records a short burst of output higher than the array produces in clear midday sun. What explains it?
Skip ahead to the key and the reasoning
Clipping caps the output at the inverter's limit; it cannot create a burst above normal production.
Near a cloud's edge, direct sun plus light scattered and reflected by the cloud can briefly push irradiance above clear-sky levels.
A ground fault diverts current out of the normal path and usually stops the inverter; it does not raise output.
Shade cools the cells and adds a few percent of voltage, but the shadow cuts irradiance far more, so output cannot beat clear sky.
Q29 · O&M · 13.3%
Right after a production meter is installed, the monitoring app shows the solar output as negative kilowatts at noon. What best explains the reading?
Skip ahead to the key and the reasoning
Reversed DC polarity keeps the inverter from producing at all; it would not show up as negative AC output.
A lost data connection leaves gaps or stale readings in the app but cannot reverse the sign of the production reading.
A clock offset shifts when production appears in the app but leaves the reading's sign unchanged.
A current transformer reads direction from how it faces the current flow, so one installed backward reports production with the wrong sign.
Q30 · Sales & economics · 10%
A system of 24 modules rated 400 W each feeds an 8.0-kW (AC) inverter. The installed price is $26,400, and a utility rebate of $2,400 lowers the owner's cost. What is the net installed cost per DC watt?
Skip ahead to the key and the reasoning
Worked answer: A
Net cost
$26,400 − $2,400
=
$24,000
Array DC rating
24 × 400 W
=
9,600 W
Cost per DC watt
$24,000 ÷ 9,600 W
=
$2.50/W
Net installed cost per DC watt
$2.50/W
The net cost is $26,400 − $2,400 = $24,000, the DC rating is 24 × 400 W = 9,600 W, and $24,000 ÷ 9,600 W = $2.50/W.
$2.75/W divides the full $26,400 price by the DC rating, leaving out the rebate the question asks you to apply.
$3.00/W uses the net cost but divides by the 8,000-W AC inverter rating instead of the 9,600-W DC array rating.
$3.30/W divides the full price by the AC inverter rating, repeating both the rebate error and the rating error.
0 / 30
Running score
Built on the 2026 outline
Each question is tagged with one domain of job task analysis version 2026.2, and the mix follows the job task analysis weights: Safety, Core Knowledge and Design supply the most questions, Sales & Economics the fewest. None is taken from a NABCEP exam or from NABCEP's practice exams.
No question cites an article of the National Electrical Code. The board's 2026 reading list for this exam names two editions of the code, and article numbers and some values moved between them, so the questions stay with principles that hold under either edition.
A timed second run
Take the set untimed the first time, reading every note. On a second run, hold yourself to a little under two minutes a question, which is the pace the exam's time limit allows for its full length. The exam itself is longer than this set and includes unscored pilot items you cannot pick out, so the pace matters more there than here; the full format sits on the PV Associate exam facts page.
Calculations in the set
A handful of questions need arithmetic from values given in the stem: data sheet ratings, energy estimates, costs and savings. The computer exam puts a calculator on screen and bars personal ones from the room, so a plain calculator is the right tool here too. After you answer, a calculation question lays out its steps with the units carried through each line.
The PV Associate study guide works two more examples, and the board offers practice exams of its own, as the row below records.
Parameter
Figure
As published
Source
NABCEP's own practice exams
NABCEP offers online practice exams for the PV Associate
PV Associate study guideThe six PV Associate domains: weights, tasks, worked math, practice items
Practice for the PVIP board exam
PVIP practice testFree practice questions in the four domains, worked code math, a note on every option
Using this PV Associate set
How long is the PV Associate exam, in questions and in time?
70 questions, 60 of them scored, in up to 2 hours. For scoring, pilot items and retakes, open the exam facts page.
Which PV Associate domain deserves the first practice session?
Start where the outline puts the most weight: Safety and Core Knowledge carry 20% of the exam each. When you finish, check the domain label on every question you got wrong; the domain with the most wrong answers is your next study block.